Address
Caochang Industrial Area, Liguang Rd, Lishui, Nanhai, Foshan, Guangdong, China
Phone:
0086-20-8938 9313
0086-757-8938 9313
Email:
Work Hours
Monday to Friday: 8AM - 10PM
24x7 online service
Custom LED Light Box & SEG Display Manufacturer


Two units can both be described as “high brightness” and behave completely differently in a shop window. The reason is that brightness is not one number. It is a measurement of light leaving the graphic face, taken at a stated distance, with a stated meter, at stated points. Remove any of those conditions and the figure stops being a specification and becomes a marketing line.
For a light box, the useful unit is luminance at the face, usually expressed in candelas per square metre (cd/m², often called nits). Illuminance in lux measures light falling on a surface and is a different quantity. A supplier quoting lux for a light box is either measuring the ambient light or using the wrong instrument.
Brightness disputes are almost impossible to settle after delivery unless the target was written down properly. The buyer says the window display looks washed out at midday. The supplier says the unit meets the quoted figure. Both can be right, because nobody agreed where to measure or what the window faces.
A checkable target protects both sides. It tells the factory what to build, it tells the installer what to expect, and it gives the goods-in team a pass or fail test that does not depend on opinion.
Face brightness is the result of four choices working together: the number and output of LEDs, the distance between the LEDs and the graphic, the diffusion material, and the driver setting. Changing one without the others moves the result in ways that are hard to predict.
| Location | Typical target range | What drives the choice |
|---|---|---|
| Interior retail, controlled lighting | 2,000–3,000 cd/m² | Balance with ambient light; avoid glare on nearby surfaces |
| Shop window facing a bright street | 3,000–5,000 cd/m² | Daylight competition and reflections on the glass |
| Shopping mall concourse | 2,500–4,000 cd/m² | High ambient light and long viewing distance |
| Outdoor signage | Higher than interior, model dependent | Direct sun, viewing distance and local rules on light spill |
| Photography or video backdrop | Matched to camera and lighting | Flicker, colour temperature and exposure |
These are planning ranges, not catalogue promises. The approved sample and the written test method define what your order must meet.
| Target | What the buyer notices | What it costs in the design |
|---|---|---|
| Around 2,000 cd/m² | Comfortable interior reading; may look flat in daylight | Lower LED count, simpler thermal design |
| Around 3,500 cd/m² | Holds up in a bright interior or a covered window | More LEDs, better diffusion, more heat to manage |
| Around 5,000 cd/m² | Reads in a sunlit window; can glare at night | Higher output, dimming may be needed, driver quality matters |
A unit can hit a brightness figure at the centre and still look wrong, because the corners are darker than the middle. Uniformity is the ratio between the darkest and brightest measurement points across the visible face. It is the parameter buyers notice first, and it is the one most often left out of a purchase order.
Ask for both. A target of “3,000 cd/m² average with ≥85% uniformity across nine points” is a specification. “High brightness” is not.
| Worth it | Skip it |
|---|---|
| The display faces a street or a glazed facade with daylight competition | The unit sits in a dim interior where a softer face reads better |
| Viewing distance is long and the graphic carries small text | The viewer stands within a metre and the message is simple |
| The installation runs through the night and must stay legible | The site has strict light-spill rules and dimming is not available |
| Photography or broadcast requires a controlled face | Nobody will photograph or film the display |
No. A unit that is too bright for a small interior creates glare, washes out nearby products and can be uncomfortable at night. Match the target to the site and check whether dimming is available.
A practical target for a quality SEG light box is at least 85% across the visible face, measured at nine points. Lower-cost units often measure much worse in the corners.
Yes, with a luminance meter at the agreed distance and points. If the meter is not available, agree a documented visual check against the approved sample and record the lighting conditions.
It does. The driver sets the current delivered to the LEDs. A driver running at its limit can produce a brighter face at the cost of heat and service life, which is why the driver model belongs in the specification.
Usually yes, for the same face size. The difference may be small per unit but matters across a multi-store rollout, so ask for the power figure per unit at the quoted setting.
Tell us the visible size, mounting position and the depth you are considering. We will check frame clearance, diffusion distance and service access against your drawing, and reply with the profile that fits the site rather than the profile that is easiest to ship.
Prefer a form? Use the contact page and attach the drawing or a photo of the site.